It was always fine before. What is the problem? We like that this pool timer because it is made from heavy-duty material and two grounded outlet makes it safe and durable. Replace the plastic insulator cover, turn on the power, and observe the visual motor check. Look at the copper tabs on the back and observe the action as you flip the switch manually on and off. My pool timer is in the off position and it is still running. If you need to set the time, you will need to take two fingers and slightly pull the wheel towards you and away from the back of the timer box. Intermatic Pool Timer Troubleshooting & Repair Guide - WeT HeaD Media The problem lies where the power dies, youve probably heard that before. My timer works good it turns on and off when I set the time. Hi Rich, is one of those wires (white?) For additional tripper pairs on CLOCK-DIALorder 156T1978A. Gears are moving , clock is seated correctly and everything is wired per diagram now that pool season is here I have to manually turn my pool on and off at the timer . Keeping a pool operational is expensive enough anyway, so every saving you can make helps. After this has been removed, you can turn the breaker back on and measure for the voltage on the timer input. Dont know what the issue is. If you find no answers readily apparent, then replace the timer mechanism they dont last forever! Read Book Tork Trippers Manual Guide Pdf For Free Sea Kayaking The World Almanac Road Trippers' Guide to National Parks: 5,001 Things to Do, Learn, and See for Yourself Dream Trippers The Little Road Trip Handbook Technical Manual War Department Technical Manual Canadian Mining Journal. Thanks in advanced. 'Why not Toowoomba?': Tourism body says water park a missed opportunity You could spray some light lubricant like WD-40 or 3-in-1 oil onto the gears both for the motor and behind the dial. My Polaris booster pump ONLY turns on via the trippers. i have an oval pool that is closed for the winter but there ha been a problem. Thank you. Look into the visual motor check window, near the top of the timer mechanism. Motor runs past the on dog but doesnt flip pump on? The tripper will not move. I looked through the visual motor check and the gear still moving fine. Use Green ON tripper for T100 Series timers and the silver ON tripper is for all other models. Intermatic 156T1978A Timer Switch Trippers, Intermatic Timer Parts White is usually neutral (for 115V power), and black/red are usually hot, but sometimes people dont always use the correct wire color. Hello, I notice today that my pump wasnt running so I opened the pool breaker panel where the timer is and noticed the breaker was tripped. So, the off dog just slips across the switch and doesnt allow the switch to turn off the motor. However, the timer will stop around 10pm everyday and will not continue moving forward again. Just some ideas. But first, pull the mechanism from the box by releasing the tab at the top (be sure breaker is turned off, first), and inspect the gears and copper tabs on the back, to look for something clogging up the works, insects, lizards, sand, etc. I believe its the manual on/off switch that is the problem. Open following links to identify timer and then add a comment. Thanks for any help you can give. Ive seen it happen from lightning strikes, or insect infestation. As an Amazon Associate we earn from qualifying purchases. Hi Bob, you have two blacks and one neutral? PDF Model: PF1103T TIME CONTROL WITH FREEZE PROTECTION - Heritage Pools, LLC Advice? Also be sure that the front dial is engaged with the gear located behind the dial. The pointer should point straight down, and you pull out on the dial, to set the correct time, aligning the current time with the pointer. If the motor gears are not turning, check the wire tightness (Breaker off first), and depress the tab at top to inspect the rear of the mechanism, to see if anything looks funny back there. Types of Pool Timers & How They Work - Pool Research Pool Pump Timer Not Working - Pool Research Are the trippers slid all the way onto the dial fully? Hi there, the ground wire? Also be sure that the dial is not pulled out, but is engaging the gear behind the dial. A wire inside the motor may be touching another wire, or the metal sides of the motor. Sometimes the on/off switch on Intermatic and other mechanical timers can get tight. Because a pool timer is an electrical timer with mechanical aspects, the clock dial portion of the timer pulls out to set the time. Two days ago after my pool pump shut off automatically I decided to turn it back on because the pool was still dirty. Does the manual lever stay in the on position always? If it doesnt improve, inspect the contacts behind the time clock for insect infestation. If your timer pins have not moved that means there is no power to the timer or the timer has failed and need to be replaced or possible manual over ride switch for the timer is off. Are the gears engaged, in the center, behind the dial? The screw in the center point timer occasionally comes loose due to vibrations from the pump and filter. Thanks again for your help. Reddit - Dive into anything Some of the most common issues for a pool pump timer not working are: power outage, incorrectly positioned yellow clock wheel, loose timer trippers, faulty internal timer, and a worn-out motor. Just replace it and hope for one that isnt defective. Your timer is on a 24-hour cycle. You can find this in your power board. So if you see the 10am behind the time marker, this means that the timer has the current time of 10am. What was the fix?? There is a lot of water that is making the cover sink and I dont want to keep filling the pool with water trying to get the cover up/. I replaced T104 timer it runs and shuts off with no issue but once off the timer does not move or turn back on. . "name": "In The Swim",
Spray WD-40 or any kind of lubricant onto the manual lever to loosen it. If none of the above suggestions resolves your issues or the issues continue to persist, it may be a good idea to purchase a new Intermatic timer for your pump. Hi Carlos, is there a GFCI outlet in the circuit? Was a good island when all the day trippers left - Review of South Sea Also check that the motor number is compatible with your clock model. "height": "219",
Sometimes its way quick just to replace it rather than spend hours troubleshooting. Reset the clock to the correct time. If any of these issues occur your timer will not work properly. Much like your timer pointer, the trippers can become loose and move around as well. Commonly, many pool owners will think there pool timer is broken and not working when all they had to to is turn the circuit breaker to the on position. Thanks Reid. If your 120V wires are properly colored, the White wire connects to terminal A, and the Black wire connects to terminal 1. Intermatic timers are a great addition to your pool set up but they can go wrong. Also, once it reaches the tripper, the gears in the window no longer move. Thank you. Copyright 2022 In The Swim. I just replaced an Intermatic WG1573-10D timer motor. Also, does it sound like the power is not leaving the breaker? "url": "https://x1.adis.ws/v1/media/graphics/i/lesl/its-logo-wide"
I can, however, hear an intermittent click as if the mechanism is trying to switch on. Intermatic pool timers allow you to set specific run-times for your pool filter pump, booster pump, and waterfall pump, so they operate at the most convenient time, or during non-peak energy hours. Or the switch can suffer wear over many years, and might not make solid contact. You will first want to look at the pool timer and see if you have two timer pins. hi, I have a smart pump for my pool, the time clock turns on in the morning and at the same time I see that the pump has power but it doesnt turn on, I have to turn on manually, is it something that the electrician has to connect to the pump so they are synchronized? Any ideas? we purchased the house 5 years ago so not sure how old the timer is? If you dont think the mechanism is the issue, move onto the next step. It could also be loose wires, either on the time clock terminal board, or on the timer motor. To adjust the time you will first want to look for the time bar that is mounted in the middle of the timer wheel. I have an intermatic timer thats 2 years young. Elite Swimming Pools TV 4.08K subscribers Subscribe 1.1K Share 97K views 3 years ago MIRAMAR Pool timer. 2425 Glenview Dr, HOLLISTER, CA 95023 | MLS# ML81913834 | Redfin I reset the breaker and tested the GCFI and I have 240V going in and out of the timer still but my pump isnt moving. It worked for a day but the day after it didnt work. I not sure if this is the best timer to use. Is it Necessary? 20 Reasons Why Pool Pumps Lose Pressure (and what to do), 25 Ways to Keep Ducks, Geese & Birds Out of Pool. So what would be the problem? When you flip the switch does it separate and reconnect the tabs? Hi Jennifer, power down (shut off the breaker) again, to see if it will switch back. Why it always stop around 10pm by itself and not moving again? The pool pump can run for 16 hours every day, which means not only will you save electricity, but you also will recover the cost of the timer within 2 years. IT happens, so I ask. },
Check the motor, and be sure the label is not printed 50 hz. Any suggestions? Is this broken? Make sure the middle time pointer is tight. Tighten down all brass screws securely, to hold all wires firmly in place. Hello have a question some what related. Home / Pool Repairs / Equipment Repairs / Intermatic Pool Timer Troubleshooting. The BN-LINK compact outdoor mechanical pool pump timer is programmable in 15-minute intervals with 48 setting options in a 24 hours period. Tork Pool Timer does not trip on - JustAnswer document.getElementById( "ak_js_1" ).setAttribute( "value", ( new Date() ).getTime() ); Professional plumber and home repairs expert, How To Remove Broken Hayward Super Pump Drain Plugs. Hi, I got the same problem as my clock not working. I have three outlets going out one to the pump , one for the salt system and one for the GFCI outlet. If the switch simply does not move side to side, it may be a bad clock, if you cannot see what is stopping it from moving. "caption": "In The Swim Blog"
There could also be other mechanical reasons for this happening, such as a disconnect in the switch. It just seems to have a weak start?? What Im wanting to do is just disable the turn off/on and just keep power 24/7. The green tripper trips the mechanism closer to the center of the dial and the gold tripper trips the mechanism towards the outer edge of the dial. The trippers can also get damaged. The terminals on the wires aren't tight. I have a intermatic T101 and the clock doesnt move I replaced the old one due to burned out motor . I guess if they look the same as before maybe the dial is warped? If test shows that timer is not turning ON-and-OFF, then timer is bad or trippers are worn and need replacement. Either that or if an older clock, the motor may be failing, or the switch mechanism worn (the part that is tripped by the tripper). Manual switch works my aerator. Any help is greatly appreciated. If soft, it may not be fully engaging the switch, which is (sort of) visible next to the tab. If your pool pump timer is beyond repair, call a professional to replace it. Since you have another switch in between the breaker and clock, the breaker will lose power when the switch is turned off. However, since I did that the time clock stopped working I looked at the motor visual window and nothing is moving. There is a second switch between the breaker and the timer. "contentUrl": "https://x1.adis.ws/v1/media/graphics/i/lesl/its-logo-wide",
When the power goes out, the timer stops. Now Im having to turn my pool pump on and off manually. Hi Rhomell, are you sure you got the correct trippers? Is the dial bent or warped? If I manually flip the switch nothing happens. Above you said to connect white to A. and Black to 1what do I do with red? "url": "https://x1.adis.ws/v1/media/graphics/i/lesl/its-logo-wide",
If its not, then the timer will not turn on/off at the correct times. (usually not). It is still moving and it will trip off but not on. I have Model T40004RTe. {
Intermatic timer won't turn on/off pump. | Trouble Free Pool Check that the breaker is firmly pushed onto the bar, and is not loose. Could I send you a picture of my setup? P.S. No luck. "thumbnailUrl": "https://x1.adis.ws/v1/media/graphics/i/lesl/its-logo-wide",
Yes, seen that before! Theres power to the pump using the manual override. Clean the gears with a toothbrush if you see debris or gunk in them. LIMITED TO A ONE-TIME RUN OF 666 UNITS. Or is there anything else I can check? I have an Intermatic t104. South Sea Island Accommodation: Was a good island when all the day trippers left - See 160 traveller reviews, 205 candid photos, and great deals for South Sea Island Accommodation at Tripadvisor. How can it keep time if lever is in off position (manual lever). Tork timer not keeping time | Mike Holt's Forum Replace them if they appear to be bent. If not, Turn off breaker, release the mechanism with the tab on the inside top, to drop the mechanism forward. 3 Baths. T104 mechanisms (without the box) are cheaper than buying the mech + box, but if your box is old with rusty hinges, missing gaskets, latch that wont work, it may be best to replace the box as well. 110V or 220V? I have a white, red, and black wire coming from the power source. After a few days its off by 6 or 7 hrs but still turns on and off fine any suggestions? Ask Your Own Pool and Spa Question be sure the pins are pushed onto the edge of the dial fully. This site is owned and operated by AJH Trade Group. The mechanism for the off tripper doesn't work at all when manually depressed. I have replaced my pool timer 3 times in the last week and they will work for a day then quit working any idea what the problem could be? Your incoming power leads should connect to terminals 1 and 3, and the wires that lead to the pump, should be connected to terminals 2 and 4. Leave the paper inside your timer box so that you do not mistakenly misplace it. }
. In most cases like this, replacing the trippers is the solution. Should I go ahead and spray it anyway? Grab it, pull it towards you, move it around then place it back down. The pool was running on a timer. I dont see any debris blocking the off dog. Using a tester i noticed that there is no power going thru the lines for the pump and salt system. GFCI breakers trip at a very low threshold, doesnt take much. I replaced the fuse(BUSS 300v GLR 3) as well. 9 Problems with Intermatic Timers and How to Fix Them - My Perfect Pool It has 4 screws below the dial labeled from left to right: LINE 1, LINE 2, LOAD 1, LOAD 2. My pump has a plug. This will cause issues such as the pump not switching on or off to the pump turning on or off at incorrect times. Pump operates off schedule Power failure earlier Reset timer Breaker was OFF for some time Reset timer 4. Lately, the timer mechanism on my old T104R does not move. Hi Dave, my pool timers not working but when I look in the little window I do see the largest back gear turning (possibly the yellow time plate gear as that appears to be moving..yet not keeping correct time.) Tighten them with a wrench. Read Book Tork Trippers Manual Guide Pdf For Free - twiki.skotos The problem is the 'off' tripper. It started lagging again a week or so ago. the trippers are even slightly damaged the timer won't work correctly. #1. Is that a faulty motor? Some white lithium grease on the switch can help in some cases. "@type": "Organization",
Replaced complete new timer assuming 5 years perfect service probably wore it out. Watch these tips and tricks before replacing it. If the power has gone out, your just opening your swimming pool for the season or some third reason, you may need to adjust the time on your Intermatic swimming pool timer. Donna Simpson Eating Website But What Toilet? The A terminal is not normally used, unless you have a 3 wire service. Electrical Monke Aug 25, 2021 #22 It's broken. Look for any disconnected or damaged wires leading to the motor on the rear of the clock. I flicked the switch between on and off and it will not shut off. If you look closely, you should be able to discern if this is the problem, which could mean a new clock. You could be missing the timer pins, you could have a bad timer, you could have no power to the timer or maybe even the timer is set wrong and it really is working but your not seeing it. Also be careful not to loosen the timer pins to much or they could fall off the timer wheel and onto the ground. Also I have rotated the dial several times to trip on and off hoping that it lubricates the problem lever and dusts off the coil well. The T104RD89 timer will work with a swimming pool motor as long as the motor is 240 VAC and is under 5 HP which is what this timer is rated for. $829,900. Hi, Using Your Timer to Optimize Your Pool Pump Download Article 1 Check the chemical balance of your pool. To reset the time clock to the correct time, grasp the outer edges of the large yellow dial, and pull gently outward. How to Install the Trippers on Intermatic Timers | eHow Sometimes bugs get in there and jam the gears, sometimes debris is the issue and other times the gears get old and may lose a tooth. To inspect, shut off power at the breaker, and push on the clip at the top of the box, to allow the mechanism to fall forward, and then you can inspect the vertical copper bars, and see how they shift and come apart (or not), when the switch is turned to off. We had a storm last week and the yard flooded my pool so I went and switched the pool off at the breaker so it would not come on with the tabs until we were able to handle the pool. If the timer manual switch isnt jammed and freely moves into the On and Off positions, then there is either no power to the timer, the timer itself has a fault, there is an issue with the wiring or the pool pump is faulty. I have a PF1112T. If the motor or wires are faulty in your Intermatic time clock, its time to replace the mechanism. I tried to change the on tripper due to Daylight savings time & dropped the screw. The capacitor for the motor may be bad. We are on our third timer. Miriam, I would check that the timer dogs are pushed fully onto the dial, and the dial is tight also check the screw for tightness in the center of the dial. Timer must be reset for current time after power outage. Your email address will not be published. Deep down, I figured it was something I did wrong and it was. Hi Davy, Any suggestions on how to troubleshoot? Please let me know if you find the solution! screwfindinganame on June 18, 2013 at 11:36 pm So what you will need to do next is to troubleshoot your Intermatic timer with a few steps. Watch these tips and tricks before replacing it. charging for timer($150.00) and filter cartridge replacement ($90.00) and a gasket($25.00)called bc of a hose leak, assume that is the gasket but then told that the other 2 parts are needed. It also provides a selectable voltage switch that enables you to choose between 120 and 240V, depending on what voltage you use and also has a battery backup option. I manually turn it on timer is running, it will trip pump OFF. Would I suspect this is a defective motor? Flip it from where it is now, to the opposite side. Other than a couple of weeks, we have spent fifteen years manually turning on our pump. The timer seems to get stuck prior to reaching the on trippers therfore the pump cant turn on. Electricity is dangerous and can kill you if you dont know what youre doing. See the wirig diagram in the owners manual here: https://www.intheswim.com/images/PDFs/E2412_Owners_Manual.pdf Clock motor power, as shown in the wiring diagram, comes from terminal 1 and also terminal 3. Learn more about pool care and repair. So I connected all leads as on the directions and the clock and on off manual switch working.Not sure if timer was never connected or someone disconnected it. Is this a bad timer mechanism or loose wire? Take them off and inspect them. I have a sweeper set on auto on the second timer and it is working correctly. Now try to jiggle it on and off. If still not working, check the wire connections and then test voltage on the clock incoming wires, outgoing wires, and then at the pump motor the problem lies, where the power dies, as they say. Ive got a weak pump battery so every time the mechanism shuts off it looses time. If the pump comes on, you definitely have power to the timer. Check that the motor gears are still moving also, when it gets to the switch and the dial stops moving. Put a meter on the wires or trace them back to find out their voltage and source. David, check the wiring, the power in and power out wires may be reversed. Monday the clock face was free spinning, today when I got home it had broken and fallen off. To check this, try to pull out the clock dial and then move it to the correct time and press it back down again. Garden Guides | How to Troubleshoot a Swimming Pool Timer I have to reset the time every day. You can turn that yellow dial by hand CW to see if the trippers hit the off and on switch and to set the time on it. "publisher": {
Is the timer repairable, or should I just install a new one? With power off, you could also check the tightness of the on/off switch, it may be missing the tension spring also, check that its there. Ill revise the scathing review I gave the unit on Amazon ratings to reflect the change. How can I fix this? on two occasions the plug from the pump almost melted and the second time the pool pump plug had to be replaced and i discontinued using the timer and disposed of it. Or fold the cover to one side if needed. If thats all ok, shut off breaker and depress tab at the top, to release the mechanism from the box, and look at the copper tabs in the back. the problem lies, where the power dies as they say.